  • Advanced Self-Operated Pressure Regulator with Receiver Tube Length Options
  • Advanced Self-Operated Pressure Regulator with Receiver Tube Length Options
  • Advanced Self-Operated Pressure Regulator with Receiver Tube Length Options
  • Advanced Self-Operated Pressure Regulator with Receiver Tube Length Options
  • Advanced Self-Operated Pressure Regulator with Receiver Tube Length Options
  • Advanced Self-Operated Pressure Regulator with Receiver Tube Length Options
Find Similar Products
  • Overview
  • Product Description
  • Structure Features
  • Product Parameters
  • Product Materials
  • Pressure adjustment method
  • Valve Maintenance
  • Production application
  • Company Profile
Overview

Basic Info.

Model NO.
AOC-3112
Standard
Standard
Connection Mode
Flange
Power
Pneumatic
Material
Stainless Steel
Type
Self-Operated
Nominal Diameter(DN)
20-300
Length of The Receiver Tube (B)
383-2200
Flange Face Distance L(Pn16/25/40)
150-850
Flange Face Distance L(Pn64)
230-900
Pn16 Weight as an Example
26-675
Flow Character
Quick-Open
Body Mat.
A216wcb
Seat Mat.
316ss+Stl
Stem Mat.
316ss+Solution Treatment
Packing
PTFE
Bonnet Type
Bellows
Effective Area
1000 Cm2
Temperature Range
-20 Degree~250 Degree
Allowable Leakage
Class IV (Hard Seal)/Class VI (Soft Seal)
Flange Standard
GB/T9113-2000/Jb/T79.1-94/Jb/T79.2-94/ Hg2059
Transport Package
Wooden
Trademark
SNT
Origin
China
HS Code
8481804090
Production Capacity
500000PCS/Year

Product Description

Product Description


Introducing the AOC-3112 Model Self-Operated Pressure Regulator Valve with Pilot - a marvel of engineering excellence that harnesses the inherent energy of the regulated medium as its own power source. This innovative valve, requiring no external energy, features a pilot that deftly manages the valve core's position, thus masterfully adjusting the medium's flow rate. It ensures unwavering stability in downstream pressure (Type B) or upstream pressure (Type K), making it indispensable in scenarios demanding precision, such as 50 mmH2O environments. Type B excels when upstream pressures range from 0.2-0.8 MPa and low downstream pressures from 0.5-100 KPa are required. Meanwhile, Type K is the preferred choice for nitrogen purging systems, seamlessly integrating with nitrogen supply systems.

Structure Features

1. The pressure setting is elegantly executed on the pilot, offering a seamless, swift, and effortless experience. It is remarkably time-efficient, allowing for continuous adjustments even during operation. With its precise control capabilities, this valve is perfect for high-precision applications.
2. This valve stands out with a broader adjustment range compared to standard self-operated valves, enhancing its versatility.

3. Engineered for sensitivity, this valve excels in detecting even the slightest pressures, such as an impressive 50 mm H2O, or minute pressure changes, delivering unparalleled performance.
4. Exhibiting an exceptional pressure reduction ratio, it is capable of handling significant differentials. For instance, with an upstream pressure of 0.8 MPa and a downstream pressure of 50 mm H2O, the differential ratio phenomenally reaches 1600.

For inquiries regarding the application of our other cutting-edge products, including self-operated micro-pressure regulator valves, differential pressure regulator valves, temperature regulator valves, flow regulator valves, and liquid level regulator valves, please reach out to our esteemed SNT Technical Department for expert guidance.

Product Parameters


Advanced Self-Operated Pressure Regulator with Receiver Tube Length Options
Nominal diameter(DN) 20 25 32 40 50 65 80 100 125 150 200 250 300
Length of the receiver tube (B) 383 512 603 862 1023 1380 1800 2000 2200
Flange face distance L(PN16,25,40) 150 160 180 200 230 290 310 350 400 480 600 730 850
Flange face distance L(PN64) 230 260 300 340 380 430 500 550 650 775 900

Pressure adjustment range
KPa
15~140 H 475 520 540 710 780 840 880 940 950
A 280 308
120~300 H 455 500 520 690 760 800 870 900 950
A 230
280~500 H 450 490 510 680 750 790 860 890 940
A 176 194 280
480~1000 H 445 480 670 740 780 780 850 880 930
A 176 194 280

PN16 Weight (Kg)
PN16 as an example
26 37 42 72 90 112 130 169 285 495 675
 

Product Materials

Part name Materials

Valve body
A216 WCB,A351 CF8/CF3/CF8M/CF3M,ZG230-450,ZG0Cr18Ni9Ti,ZG0Cr18Ni12Mo2Ti

Spool
304SS,316SS,304LSS,316LSS,1Cr18Ni9,  0Cr18Ni12Mo2Ti
(Stellite Clad welding Stellite)   PTFE

Valve seat
304SS,316SS,304LSS,316LSS,1Cr18Ni9,0Cr18Ni12Mo2Ti (Stellite Clad welding Stellite)
Stem 304SS,316SS,304LSS,316LSS,1Cr18Ni9,1Cr18Ni9,0Cr18Ni12Mo2Ti   
Rubber diaphragm Nitrile,ethylene,fluoro,oil resistant rubber ,0Cr18Ni9Ti
Membrane cover   Q235,Q235 Painting PTFE

Packing
  
Polytetrafluoroethylene,flexible graphite

Pressure adjustment method


The self-regulating pressure valve arrives pre-adjusted to a specified set value. Should you wish to modify this setting or if the actual indication deviates for any reason, adjustments are straightforward. To reduce pressure, simply rotate the adjusting bar with the provided turning piece 7 (adjusting disc) clockwise. Conversely, increase pressure by turning it counterclockwise, ensuring perfect alignment with your requirements.

Valve Maintenance

Trouble shooting Causes of production Exclusion methods
Unstable post-valve pressure with 1,Spool stuck by foreign objects
2,Valve stem, push rod jammed
3,Fluid inlet pipe blocked

1,Reinstallation to exclude foreign objects
2,Re-adjustment
3,unclogging
,pressure changes in front of the valve
1,Set spring stiffness is too large
2,The valve bore is too large
3,The pressure before the valve is too high, the pressure reduction ratio is too large

1,Replacement of springs
2,Replace the smaller diameter
3,The pressure before the valve and the pressure after the valve exceed 20, should be 2 levels of pressure reduction
Pressure behind the valve does not drop, always above the demand value
1,Set spring stiffness is too small
2,The valve bore is too small
3,The pressure reduction ratio is too small

1,Replacement of springs
2,Replace the larger diameter
3,Pressure before the valve: the pressure after the valve is lower than 1.25, the pressure before the valve should be increased
Pressure behind the valve does not rise, always below the demand value 1Set spring stiffness is too small
2,The spool is stuck by a foreign object
3,Valve stem, push rod jammed
4,The spool and seat are damaged, the leakage is too large
5,The valve bore is too large

1,Replacement of springs
2,Reinstallation
3,Re-adjustment
4,Re-grind, or replace
5,Replace smaller diameter
Pressure behind the valve does not rise and always moves below the demand value 1 Set spring stiffness is too large
2,The valve bore is too small
3,The spool, stem, push rod, etc. are stuck

1,Replacement of springs
2,Replace larger diameter
3,Exclude the cause of jamming and readjust
Pre-valve pressure does not drop, always moves above the demand value
1,The valve bore is too large
2,Actuator membrane chamber capacity is too small
Select the proper valve diameter
2,Add a damper in the inlet pipeline
 
Advanced Self-Operated Pressure Regulator with Receiver Tube Length Options
Advanced Self-Operated Pressure Regulator with Receiver Tube Length Options
Advanced Self-Operated Pressure Regulator with Receiver Tube Length Options

Instructions for Ordering

Valve type   Valve name  
Nominal diameter (mm) Nominal pressure (Mpa)
Pressure adjustment range (Mpa)   Control valve before or after
Pressure setting value (Mpa) Name of medium
Actuator type   Medium working temperature
Rated flow coefficient   Medium state
Max. pressure before valve
Minimum pressure before valve
Normal pressure before the valve(Mpa)
Max. pressure after valve
Min. pressure after valve
Normal pressure after valve (Mpa)
Maximum flow rate
Minimum flow rate
Normal flow rate
  Viscosity of liquids
Liquid density
Gas density
 
Material:Valve body
Valve internals
  Leakage level requirements
(GB/T4213-92)
 
Process piping dimensions Corrosion resistance requirements  
Flange face distance (mm) L   Flange execution standards  
Supplied with accessories Condenser, receiver, mating flange, fasteners, regulator bar, pressure take-off tube, pressure take-off fitting


 

Production application


Advanced Self-Operated Pressure Regulator with Receiver Tube Length Options
Advanced Self-Operated Pressure Regulator with Receiver Tube Length Options

Advanced Self-Operated Pressure Regulator with Receiver Tube Length Options
Advanced Self-Operated Pressure Regulator with Receiver Tube Length Options

Advanced Self-Operated Pressure Regulator with Receiver Tube Length Options
Advanced Self-Operated Pressure Regulator with Receiver Tube Length Options
 
Advanced Self-Operated Pressure Regulator with Receiver Tube Length Options
Advanced Self-Operated Pressure Regulator with Receiver Tube Length Options
 

Company Profile

Advanced Self-Operated Pressure Regulator with Receiver Tube Length Options



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier